Add to Cart
MEASTEK MDP5300B High Voltage Differential Probe, 120MHz Bandwidth ±3000V Measurement, 1% High Accuracy Safety Certification
Key Features:
1. Professional-grade performance
supports up to 120MHz bandwidth and as low as 2.9ns rise time, accurately captures high-frequency signal details, suitable for scenarios such as switching power supplies and motor drives.
2. Ultra-high voltage withstand capability
Maximum differential voltage ±3000Vpk (MDP5300 series), meets CAT III 600V safety standards, and provides reliable high-voltage measurement guarantee.
3. Excellent accuracy and stability
The accuracy of the entire series is 1%, the input impedance is up to 10MΩ, and the input capacitance is as low as <2pF, ensuring distortion-free signal transmission.
4. Multiple safety protections
built-in overload indicator (red light warning), automatic save function, in line with international safety regulations, with CAT III/IV certified accessories, more secure to use.
5. Ready-to-use kit
Contains standard accessories such as alligator clips, test hooks, BNC output cables, compatible with USB 5V power supply, ready to use out of the box, and supports 1 year official warranty.
Specifications
Model | MDP5300B |
Bandwidth (-3dB) | 120 MHz |
Rise time (ns) | ≤2.9 |
Accuracy | 1% |
Attenuation ratio | 100X/1000X |
Maximum differential measurement voltage (DC+Peak AC) | 100X ±300Vpk |
100X ±3000Vpk | |
Effective value | 100X ±212Vrms |
1000X ±2120Vrms | |
Maximum input voltage to ground (Vrms) | 600V CATII 1000V CATI |
Common mode voltage(DC+Peak AC) | ±3000Vpk |
Input Impedance | Single-ended to ground 5MΩ |
Two input terminals 10MΩ | |
Input Capacitance | Single-ended to ground <4pF |
Two input ends <2pF | |
CMRR | DC >80dB |
100kHz>60dB | |
1MHz>50dB | |
Noise (Vrms) | 100X <100mV |
1000X <600mV | |
Delay time | Host: about 9ns |
BNC cable 1m: about 5ns | |
Overload indicator voltage threshold | 100X >300Vpk |
100X >3000Vpk | |
Overload indicator light (red light) | Yes |
Auto-save function | Yes |
Terminal load requirement | ≥100kΩ |
power supply | USB 5V/1A adapter |
Probe Standard Accessories
Name | Object | Parameters |
Alligator Clips | ![]() | CATIII 1000V CATIV 600V |
Piston probe clamp | ![]() | CATIII 1000V |
Test Hook | ![]() | CATII 1000V |
Input extension cord | ![]() | CATIII 1000V |
BNC output cable | ![]() | BNC male to male output cable (length 1 meter) |
Power output line | ![]() | Length 1 meter |
Power adapter | USB 5V/1A |
Packing List
Name | Quantity |
High-voltage differential probe | 1 piece |
Alligator Clips | 1 pair |
Piston probe clamp | 1 pair |
Test hook | 1 pair |
Input extension cable | 1 pair |
BNC output cable | 1 piece |
Power output cable | 1 piece |
Power adapter | 1 piece |
Test report | 1 serving |
Warranty card | 1 piece |
Probe box | 1 piece |
FAQ
Q1: What is the maximum safe working voltage of the MDP5300A?
A1: The voltage to ground is 600V CATII/1000V CATI, the differential voltage is ±3000Vpk (1000X attenuation), it complies with CE/UL safety certification, and has built-in overload protection.
Q2: How to choose the attenuation ratio?
A2: Select according to the voltage being tested:
100X attenuation: Applicable to signals ≤±300Vpk (such as low-voltage inverter drive circuit)
1000X attenuation: Applicable to signals ≤±3000Vpk (such as high-voltage bus, IGBT collector voltage)
Q3: What is the impact of input capacitance on the test?
A3: 2pF differential input capacitance significantly reduces the load effect:
The capacitive reactance of high-frequency signals (such as 50MHz) is only about 1.6kΩ, which is much lower than that of traditional probes (5pF capacitive reactance is about 800Ω)
Measured comparison: Similar probes increase the delay of the rising edge of the IGBT drive waveform by 1.2ns, while the delay of MDP5300A is only 0.3ns