Add to Cart
1. Wide Current Measurement Range: 60A to 1200kA
2. High Accuracy:
3. Bandwidth Flexibility:
4. Compact Design:
5. Application Scope:
1. Lightweight and Flexible Coil Design
2. Ultra-low interference performance
3. Flexible power supply options
4. Customization capabilities
Model | Input Interface | Current | Circumference & Lead Length | Output Interface |
MCT | D (Direct Connection) | Selected based on maximum range | 700MM / 300MM (Optional) | Two output interface options: G: Industrial terminal, 24V power supply (H) S: SMA interface, 5V power supply (L) |
B (BNC) |
Model | MCTD/B XXXXA3 | MCTD/B XXXXA7 |
Flexible Probe Circumference (Typical Value, Customizable) |
300mm | 700mm |
Inductive Loop Outer Diameter (Typical Value) | 8mm | 8mm |
Inductive Loop Connection Cable Length | 1m (Customizable) | 1m (Customizable) |
BNC Connection Cable Length | 1m or 2m, standard: 1m | 1m or 2m, standard: 1m |
Model | Sensitivity (mV/A) | Peak Current (A) | Maximum Noise (mVrms) | Low-Frequency Bandwidth -3dB (Hz) | Phase Shift (50Hz) | Peak di/dt (kA/µs) |
High-Frequency Bandwidth -3dB |
||
300 mm |
700 mm |
||||||||
MCTD |
MCTD0120A |
50 |
120 | 1 | 0.6 |
<0.95° |
0.2 |
1MHz |
600kHz |
MCTD0300A |
20 | 300 | 1 | 0.6 |
<0.95° |
0.2 | |||
MCTD0600A |
10 |
600 |
1 | 0.45 |
<0.85° |
0.25 | |||
MCTD1200A |
5 | 1200 | 1 | 0.23 |
<0.5° |
0.5 | |||
MCTD3000A |
2 | 3000 | 1 | 0.15 |
<0.35° |
1.2 | |||
MCTD6000A |
1 | 6000 | 1 | 0.1 |
<0.25° |
2.5 | |||
MCTD012KA |
0.5 | 12K | 1 | 0.08 |
<0.2° |
5 | |||
MCTD030KA |
0.2 | 30K | 0.5 | 0.07 |
<0.18° |
6 | |||
MCTD030KA |
0.1 | 60K | 0.5 | 0.07 |
<0.18° |
6 | |||
MCTD030KA |
0.05 | 120K | 0.5 | 0.07 |
<0.18° |
6 |
Model MCTDXXXXA3: 300mm circumference, 1MHz bandwidth ; MCTD XXXXA7: 700mm circumference, 600kHz bandwidth
Environmental Parameters:Temperature: 23°C ±1°C;Humidity: 60% RH ±5%
Operational Requirements:The measured conductor must pass vertically through the center of the probe induction loop.
This table specifies the model based on current rating and circumference. Please confirm the interface type with our company when selecting a model to ensure the final specification meets your requirements.
Typical Accuracy | ±1% |
Maximum Output Voltage | ±6Vpk |
Probe Loop Withstand Voltage | 10kVpk |
Terminal Load Requirement | ≥100kΩ |
Power Supply | SMA Connector (5V Adapter), Industrial Terminal Connector (24V Adapter) |
Safety Compliance | EN61010-1:2010 |
EMC Compliance | EN61326-1:2013, EN61000-3-2:2014, EN61000-3-3:2013 |
Operating Temperature | Probe Ring | -20°C to +70°C |
Main Unit | -10°C to +55°C | |
Storage Temperature | -30°C to +70°C | |
Operating Humidity | ≤85% RH (Non-condensing) | |
Storage Humidity | ≤90% RH (Non-condensing) |
Name | Quantity |
Integrator | 1 piece |
Flexible Coil | 1 piece |
USB Output Adapter (5V/12V/24V) | 1 piece |
USB Power Cable | 1 piece |
BNC Output Cable | 1 piece |
Digital User Manual | 1 copy |
Warranty Card | 1 card |