MEASTEK MDP5700B High Voltage Differential Probe ±7000V Peak Measurement, Portable Laboratory-grade Tool
Key Features:
1. Extreme voltage support
Designed for ultra-high voltage, the maximum differential voltage is ±7000Vpk (1000X mode), meeting the stringent requirements of power systems, electric vehicles and other fields.
2. Low noise performance
Noise <1.2V in 1000X mode, with high-precision 1% error, weak signals and high-voltage pulses can be clearly captured.
3. Intelligent and convenient functions
Automatically save measurement data, automatic overload warning, reduce human operation errors, and improve work efficiency.
4. Lightweight and portable design
Compact probe body + 1 meter lightweight wire, with a dedicated probe box, convenient for rapid deployment in laboratory and field environments.
5. Full-scenario compatible accessories
Standard CATIII 1000V probe clip, test hook and extension cable, compatible with oscilloscopes and data recorders, plug and play without debugging.
Specifications
Model | MDP5700B |
Bandwidth (-3dB) | 120 MHz |
Rise time (ns) | ≤2.9 |
Accuracy | 1% |
Attenuation ratio | 100X/1000X |
Maximum differential measurement voltage (DC+Peak AC) | 100X ±700Vpk |
1000X ±7000Vpk | |
Effective value | 100X ±500Vrms |
1000X ±5000Vrms | |
Maximum input voltage to ground (Vrms) | 1000V CATII 2300V CATI |
Common mode voltage(DC+Peak AC) | ±7000Vpk |
Input Impedance | Single-ended to ground 20MΩ |
Two input terminals 40MΩ | |
Input Capacitance | Single-ended to ground <5pF |
Two input ends <2.5pF | |
CMRR | DC >80dB |
100kHz>60dB | |
1MHz>50dB | |
Noise (Vrms) | 100X <200mV |
1000X <1.2V | |
Delay time | Host: about 9ns |
BNC cable 1m: about 5ns | |
Overload indicator voltage threshold | 100X >700Vpk |
1000X >7000Vpk | |
Overload indicator light (red light) | Yes |
Auto-save function | Yes |
Terminal load requirement | ≥100kΩ |
power supply | USB 5V/1A adapter |
Probe Standard Accessories
Name | Object | Parameters |
Alligator Clips | ![]() | CATIII 1000V CATIV 600V |
Piston probe clamp | ![]() | CATIII 1000V |
Test Hook | ![]() | CATII 1000V |
Input extension cord | ![]() | CATIII 1000V |
BNC output cable | ![]() | BNC male to male output cable (length 1 meter) |
Power output line | ![]() | Length 1 meter |
Power adapter | USB 5V/1A |
WARNING: To avoid the risk of electric shock or fire, do not use the MDP5700A/ MDP5700B/ MDP5700C probes or hook tip accessories on CAT III or CAT IV circuits. To avoid the risk of electric shock or fire, do not use the MDP5700A/ MDP5700B/ MDP5700C test probes or hook tip accessories on circuits above 7000V when using the MDP5070A/ MDP5070B/ MDP5070C probes.
Use only accessories rated for the application. Substituting other accessories may create a risk of electric shock or burns. Keep the probe body and accessories clean to reduce the risk of electric shock from conductive surfaces.
Packing List
Name | Quantity |
High-voltage differential probe | 1 piece |
Alligator Clips | 1 pair |
Piston probe clamp | 1 pair |
Test hook | 1 pair |
Input extension cable | 1 pair |
BNC output cable | 1 piece |
Power output cable | 1 piece |
Power adapter | 1 piece |
Test report | 1 serving |
Warranty card | 1 piece |
Probe box | 1 piece |
FAQ
Q1: What is the maximum safe working voltage of the MDP5300A?
A1: The voltage to ground is 600V CATII/1000V CATI, the differential voltage is ±3000Vpk (1000X attenuation), it complies with CE/UL safety certification, and has built-in overload protection.
Q2: How to choose the attenuation ratio?
A2: Select according to the voltage being tested:
100X attenuation: Applicable to signals ≤±300Vpk (such as low-voltage inverter drive circuit)
1000X attenuation: Applicable to signals ≤±3000Vpk (such as high-voltage bus, IGBT collector voltage)
Q3: What is the impact of input capacitance on the test?
A3: 2pF differential input capacitance significantly reduces the load effect:
The capacitive reactance of high-frequency signals (such as 50MHz) is only about 1.6kΩ, which is much lower than that of traditional probes (5pF capacitive reactance is about 800Ω)
Measured comparison: Similar probes increase the delay of the rising edge of the IGBT drive waveform by 1.2ns, while the delay of MDP5300A is only 0.3ns