Add to Cart
MEASTEK HDP6070 Differential Probe, 100X Attenuation ±700Vpk High Voltage Measurement, 5MHz Bandwidth And Low Capacitance Design
Key Features:
1. The ultra-high voltage probe supports ±3500Vpk differential voltage (500X attenuation probe), which is specially designed for photovoltaic test tools and is suitable for accurate measurement of photovoltaic inverters, high-voltage power supplies and other scenarios.
2. The low-capacitance differential probe has a single-ended input capacitance to ground of <4pF, which effectively reduces the attenuation of high-frequency signals and ensures the true restoration of waveforms.
3. The automatic save probe is equipped with a one-key save function, which can quickly store key data and significantly improve test efficiency.
4. The anti-interference design is adopted, with a CMRR of >50dB at 1MHz to ensure signal integrity in complex electromagnetic environments.
5. Standard CAT III 1000V alligator clips and extension cords are provided to enhance the safety of operation in high-voltage environments and meet industrial-grade testing requirements.
Specifications
Model | HDP6350 |
Bandwidth (-3dB) | 5 MHz |
Rise time | ≤70ns |
Accuracy | 0.1% |
Attenuation ratio | 500X |
Maximum differential measurement voltage (DC+Peak AC) | ±3500Vpk |
Effective value | ±2475Vrms |
Maximum input voltage to ground (Vrms) | 1000V CATII |
Common mode voltage(DC+Peak AC) | ±3500Vpk |
Input Impedance | Single-ended to ground 5MΩ |
Two input terminals 10MΩ | |
Input Capacitance | Single-ended to ground <4pF |
Two input ends <2pF | |
CMRR | DC >80dB |
100kHz>60dB | |
1MHz>50dB | |
Noise (Vrms) | <600mV |
Delay time | Host: about 9ns |
BNC cable 1m: about 5ns | |
Overload indicator voltage threshold | ≥3500Vpk |
Overload indicator light (red light) | Yes |
Auto-save function | Yes |
Terminal load requirement | ≥100kΩ |
power supply | USB 5V/1A adapter |
Probe Standard Accessories
Name | Object | Parameters |
Alligator Clips | ![]() | CATIII 1000V CATIV 600V |
Test Hook | ![]() | CATII 1000V |
Input extension cord | ![]() | CATIII 1000V |
Power output line | ![]() | Length 1 meter |
Power adapter | USB 5V/1A |
BNC output cable | ![]() | Choose 1 from 3 | BNC male to male output cable, length 1 meter (for use with measuring instruments with BNC interface such as oscilloscopes and oscilloscope recorders) |
BNC to banana plug | ![]() | BNC male to banana output cable, length 1 meter (For use with power analyzers, power meters, desktop multimeters and other measuring instruments with banana interface) | |
BNC to electronic cable | ![]() | BNC male to electronic output cable, length 1 meter (for use with measuring instruments with two-terminal signal input interfaces such as data loggers and power meters) |
Packing List
Name | Quantity | |
BNC output cable | According to the host interface type: Choose one of the three | 1 piece |
BNC to banana plug | ||
BNC to electronic cable |
High Precision Differential Probe | 1 piece |
Alligator Clips | 1 pair |
Test Hook | 1 pair |
Input extension cord | 1 pair |
Power output line | 1 piece |
Power adapter | 1 piece |
Test report | 1 serving |
Warranty card | 1 piece |
Probe Box | 1 piece |
Note: BNC male to male output cable, BNC male to banana plug output cable, BNC male to electronic cable, three types of output cables can be selected according to the host interface input type matched by the customer.