Brand Name :MEASTEK
Model Number :HCTM3000A
Payment Terms :T/T,Western Union,MoneyGram
Delivery Time :5-8 work days
Sensitivity (mV/A) :2
Current (KA) :3.0
Maximum noise (mV Vpp) :8
Low frequency bandwidth -3dB(Hz) :0.4
High frequency bandwidth -3dB(MHz) :15
Typical accuracy :2%
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

MEASTEK HCTM3000A High Frequency Flexible High Current Probe 15MHz High Frequency For Electric Vehicle Charging Pile Current Detection


1. Low sensitivity for large current measurement

The sensitivity is 2mV/A, which is specially designed for measuring large currents. It can maintain stable measurement performance at a peak current of 3.0KA, and is suitable for monitoring large current scenarios such as large power equipment and high-voltage transmission lines. ​


2. Minimum noise interference

The maximum noise is 8mV Vpp, which effectively reduces the noise interference during the measurement process and provides you with pure and accurate current measurement data. In a complex electromagnetic environment, the real current signal of the device can also be clearly obtained to help you make accurate judgments. ​


3. Stable attenuation characteristics

The attenuation characteristics are 0.4%/ms, which ensures the stability and accuracy of the measurement data. In the long-term measurement process, it can effectively reduce the error caused by signal attenuation and provide you with reliable long-term monitoring data. ​


4. Reliable high-frequency measurement capability

The high-frequency bandwidth -3dB is 15MHz. For some large current signals with high-frequency components, the current probe in complex wiring environments, such as high-frequency currents in power electronic devices, can accurately measure and meet your needs for complex current signal analysis.​


5. Convenient installation and operation

The convenient installation structure and operation method are designed, so that installation and measurement can be easily completed even in places with limited space and inconvenient operation. The simple and easy-to-understand operation interface allows you to use it without complicated training, improving work efficiency.


Specifications

Model HCTM3000A
Sensitivity (mV/A) 2
Peak Current (KA) 3.0

dI/dt(KA/μs)

25
Maximum noise (mV Vpp) 8
Attenuation characteristics(%/ms) 0.4
Low frequency bandwidth -3dB(Hz) 0.5
High frequency bandwidth -3dB(MHz) 15
Typical accuracy

2%

Insulation voltage value

2KV


HCT(S)XXXXA Series Other Technical Parameters

Maximum output voltage

6Vpk

Terminal load

≥100kΩ

Power supply mode USB 5V (standard adapter)
Operating temperature range Integrator

0℃ - 50℃

Probe ring

0℃ - 100℃

Storage temperature range

-40℃~80℃


Product Description

MEASTEK HCTM3000A High Frequency Flexible High Current Probe 15MHz High Frequency For Electric Vehicle Charging Pile Current Detection

(Take HCTS0120A as an example)


1) Input interface: current probe test signal input terminal.
2) Output interface: current probe integrator signal output terminal.
3) USB 5V power supply interface: standard USB (type B) interface. (USB power supply cable and power adapter are standard)

4) Test connection diagram.

MEASTEK HCTM3000A High Frequency Flexible High Current Probe 15MHz High Frequency For Electric Vehicle Charging Pile Current Detection


Mechanical specifications

Model HCTSXXXXA
Typical value of flexible probe circumference (customizable)

80mm

Typical value of induction ring body diameter

1.6mm

Typical value of flexible probe diameter (customizable)

25mm

Induction loop connection cable length 1 M (customizable)
BNC connection cable length 1 M or 2 M, 1 M is Standard

Integrator body dimensions

(including BN port dimensions)

About 110(L)*47(W)*30(H)mm
USB cable (AM-BM) About 1.8m
USB output adapter About 59mm*30mm*20mm
Probe weight About 150g
Box weight (including probe) About 960g


Care And Maintenance

1) Keep the probe clean and dry.
2) If cleaning is required, wipe with a soft dry cloth. Do not use chemical cleaning agents.
3) When the probe is not in use, please put it in the packaging provided and place it in a cool, clean and dry place.
4) When transporting the probe, be sure to put it in the packaging provided by our company to prevent shock.
5) Do not pull the input and output lines hard to avoid excessive twisting, bending or knotting.


Packing List

Name Quantity
Current probe integrator 1 piece
Current probe flexible induction coil 1 piece
USB output adapter (5V/1A) 1 piece
USB power cable 1 piece
BNC output cable 1 piece
Electronic manual 1 serving